Avery PC-905 Manuál s instrukcemi

Procházejte online nebo si stáhněte Manuál s instrukcemi pro Kuchyňské váhy Avery PC-905. Avery PC-905 Instruction manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - User Instructions

PC-905 Counting ScalePC-905User InstructionsENGLISH43002-0016 Issue AB June 2008

Strany 2 - Declarations of compliance

10 PC-905 Counting Scale User Instructions Scale Setup and Operation3.4 Operation as a ScaleThe PC-905 can be used as a bench scale or as a counting

Strany 3 - Contents

PC-905 Counting Scale User Instructions 113.5 Operation as a Counting Scale3.5 Operation as a Counting ScaleCounting consists of two major steps; en

Strany 4

12 PC-905 Counting Scale User Instructions Scale Setup and Operation3.6 Counting Using a Known Piece WeightSampling is just one way to get a piece w

Strany 5 - Introduction

PC-905 Counting Scale User Instructions 133.7 Counting Using Bulk Sampling3.7 Counting Using Bulk SamplingBulk sampling is an automated sampling met

Strany 6 - Keyboard and Display

14 PC-905 Counting Scale User Instructions Scale Setup and Operation3.8 Counting Using Dribble SamplingDribble sampling requires one more step than

Strany 7

PC-905 Counting Scale User Instructions 153.9 Using Reverse Sampling for Counting, Method 13.9 Using Reverse Sampling for Counting, Method 1Method 1

Strany 8 - Scale Setup and Operation

16 PC-905 Counting Scale User Instructions Scale Setup and Operation3.10 Using Reverse Sampling for Counting, Method 2Method 1 or 2 are chosen in th

Strany 9 - 3.3 Battery Power Option

PC-905 Counting Scale User Instructions 173.11 Recalling a Piece Weight3.11 Recalling a Piece WeightThe PC-905 lets you view the active piece weight

Strany 10 - 3.4 Operation as a Scale

18 PC-905 Counting Scale User Instructions Scale Setup and Operation3.16 Using the BASE KeyPress the BASE key to switch between using the local scal

Strany 11

PC-905 Counting Scale User Instructions 19This section covers the serial communications capabilities of the PC-905. In this section you will find:Defa

Strany 12 - Scale Setup and Operation

© Avery Weigh-Tronix LLC, 2006. All rights reserved.The information contained herin is the property of Avery Weigh-Tronix LLC and is supplied without

Strany 13

20 PC-905 Counting Scale User Instructions Serial CommunicationsThe functional pinout is as follows: The scale has a remote base option. If this is

Strany 14

PC-905 Counting Scale User Instructions 214.2 Preset Print Formats4.2 Preset Print FormatsImp Printer Formats 8 Formats are available with the Imp p

Strany 15

22 PC-905 Counting Scale User Instructions Serial Communications4. Ft 4 = Displayed count or weight with identifier-In COUNT MODE,<SP> CCCCCCC

Strany 16 - Method #2 - Without a Tare

PC-905 Counting Scale User Instructions 234.2 Preset Print Formats8. Ft 8 = Count only with a fixed field format-COUNT:<SP>CCCCCCC<SP>PC

Strany 17 - 3.13 Recalling a Tare Weight

24 PC-905 Counting Scale User Instructions Serial CommunicationsDymo Label Writer Setra 300 Formats

Strany 18 - 3.16 Using the BASE Key

PC-905 Counting Scale User Instructions 254.2 Preset Print FormatsZebra 2844 Printer FormatsTime and date will appear only if the printer has this o

Strany 19 - Serial Communications

26 PC-905 Counting Scale User Instructions Serial CommunicationsPC Protocol The scale's RS-232 bidirectional communication works in a master/sl

Strany 20 - Serial Communications

PC-905 Counting Scale User Instructions 274.2 Preset Print FormatsStatus Bytes

Strany 21 - 4.2 Preset Print Formats

28 PC-905 Counting Scale User Instructions Serial CommunicationsNCI Protocol Key to symbols used:<STX> Start of Text<ETX> End of Text c

Strany 22

PC-905 Counting Scale User Instructions 294.2 Preset Print FormatsThe NCI protocol may have three status bytes. The status bits are defined as follo

Strany 23 - 4.2 Preset Print Formats

PC-905 Counting Scale User Instructions 3pageContents ...

Strany 24 - 300 Formats

30 PC-905 Counting Scale User Instructions Serial CommunicationsBroadcast Protocol Broadcast protocol will support the use of the RD-4100, RD-6100 a

Strany 25 - Zebra 2844 Printer Formats

PC-905 Counting Scale User Instructions 31The error messages you might see on the display are shown below.Error Messages5Error message Error condition

Strany 26

32 PC-905 Counting Scale User Instructions SpecificationsResolution can be expanded up to 500,000 divisions depending on the application.Specificati

Strany 27 - Status Bytes

PC-905 Counting Scale User Instructions 33Internal Resolution: 1:2,000,000Dimensions: Weighing Platform: 12.6” X 14.08”, 25, 50 & 100 lb capacit

Strany 28

34 PC-905 Counting Scale User Instructions Specifications

Strany 30

Avery Weigh-Tronix USA1000 Armstrong Dr.Fairmont MN 56031 USATel: 507-238-4461Fax: 507-238-4195Email: [email protected] W

Strany 31 - Error Messages

4 PC-905 Counting Scale User Instructions

Strany 32 - Specifications

51.1 ContentsThis manual tells you how to operate the PC-905 high precision counting scale. You can configure your scale for different options and sam

Strany 33

6 PC-905 Counting Scale User Instructions Keyboard and DisplayFigure 2.1 shows the front panel of the PC-905. This is made up of the keyboard and di

Strany 34 - Specifications

PC-905 Counting Scale User Instructions 7There are three keys to the right of the display:• SAMPLE Used to select a sample size and to initiate the ca

Strany 35

8 PC-905 Counting Scale User Instructions Scale Setup and OperationThis section of the manual covers getting your scale ready to work and operating

Strany 36

PC-905 Counting Scale User Instructions 93.3 Battery Power Option3.3 Battery Power OptionThe PC-905 has an internal and an external battery option.T

Komentáře k této Příručce